A 311 |
L-Ag44 |
- |
AG 203 |
- |
Ag 244 |
- |
- |
Very good flowing characteristics, Good corrosion resistance, DVGW GW2 (suitable for the use in drinkable water), Suitable for the use in see water |
HVACR, Cooling devices, Plate heat exchangers, Copper pipes installations, Measuring instruments, Plumbing installations |
730 |
675 - 735 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
A 314 |
L-Ag55Sn |
- |
AG 103 |
- |
Ag 155 |
- |
- |
Good corrosion resistance, Very good flow charac- teristics, Low temperature melting, Suitable for the use in see water |
HVACR, Food industry, Electrical engineering, Measuring instruments, Plumbing installations, Medical instruments, Suitable for CrNi base materials |
650 |
630 - 660 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
A 319 |
L-Ag34Sn |
- |
AG 106 |
- |
Ag 134 |
- |
- |
Good corrosion resistance, Good flow characteris- tics, DVGW GW2 (suitable for the use in drinkable water) |
HVACR, White goods, Compressors, Copper pipes installations, Food industry, Plumbing installations |
710 |
630 - 730 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
A 320 |
L-Ag45Sn |
BAg-36 |
AG 104 |
- |
Ag 145 |
- |
- |
Good corrosion resistance, Very good flow characteristics, DVGW GW2 (suitable for the use in drinkable water), Suitable for the use in see water |
HVACR, Cooling devices, Plate heat exchangers, Food industry, Electrical engineering, Measuring instruments, Plumbing installations, Suitable for CrNi base materials |
670 |
640 - 680 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
A 330 |
L-Ag30 |
BAg-20 |
AG 204 |
- |
Ag 230 |
- |
- |
Good corrosion resistance, Good flow characteristics, Great color matching on brass |
HVACR, White goods, Compressors, Plumbing engineering |
750 |
680 - 765 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
A 340 |
L-Ag40Sn |
BAg-28 |
AG 105 |
- |
Ag 140 |
- |
- |
Good corrosion resistance, Good ductility, Good flow characteristics, Suitable for the use in see water |
HVACR, White goods, Plate heat exchangers, Compressors, Electrical engineering, Plumbing installations |
690 |
650 - 710 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
A 333 |
- |
- |
- |
- |
Ag 230a |
- |
- |
Good corrosion resistance, High strength, High ductility, Good flow characteristics |
HVACR, White goods, Compressors, Heat exchangers, Copper pipes installations, Plumbing installations |
790 |
676 - 788 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
A 3002 |
L-Ag2P |
BCuP-6 |
CP 105 |
- |
CuP 279 |
- |
- |
Good flow characteristics, Very good gap filling ability, DVGW GW2 (suitable for the use in drinkable water), Large gap (> 0,1mm), Gap length (< 1 cm) |
HVACR, White goods, Tubular joints, Heat exchangers (U-bogen), Heat pumps, Copper pipes installations |
740 |
645 - 825 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
A 3005 |
L-Ag5P |
BCuP-3 |
CP 104 |
- |
CuP 281a |
- |
- |
Good electrical conductivity, Good ductility, Good flow characteristics, Large gap (> 0,1mm), Gap length (< 1 cm) |
HVACR, White goods, Electrical engineering, Plumbing installations (Gas water heaters), Heat pumps, Compressors |
710 |
645 - 815 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
A 3015 |
L-Ag15P |
BCuP-5 |
CP 102 |
- |
CuP 284 |
- |
- |
Very good electrical conductivity, Good ductility a. strength, Good gap filling ability, Medium flow characteristics, Medium gap |
HVACR, Electric motors (Renewable energies), Electric supplies, Components with medium gaps |
700 |
645 - 800 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
A 3018 |
L-Ag18P |
BCuP-8 |
- |
- |
CuP 285 |
- |
- |
Very good electrical conductivity, High ductility, High strength, Very fluid, Narrow gaps (0,03 - 0,1mm), Gap length (> 1 cm) |
HVACR, Hot water treatment, Water heaters, Suitable for components that are subject to vibrations and thermal fluctuations |
670 |
645 - 666 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
A 2003 |
L-CuP7 |
BCuP-2 |
CP 202 |
- |
CuP 180 |
- |
- |
Very good flow characteristics, Medium/high fluidity, Large gap (> 0,1mm), Gap length (< 1 cm) |
HVACR, Copper pipes installations, Standard assemblies (Sleeves/Tubes/Flanges) with important gaps, Universal alloy for plumbing |
730 |
710 - 820 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
A 2004 |
L-CuP6 |
- |
CP 203 |
- |
CuP 179 |
- |
- |
Very good flow characteristics, controlled fluidity, DVGW GW2 (suitable for the use in drinkable water), Large gap (> 0,1mm), Gap length (< 1 cm) |
HVACR, Copper pipes installations, Standard assemblies (Sleeves/Tubes/Flanges) with important gaps, Universal alloy for plumbing |
760 |
710 - 890 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
A 2005 |
L-CuSnP7 |
- |
CP 302 |
- |
CuP 386 |
- |
- |
Good flow characteristics, Good gap-bridging ability, Very good wetting ability, electroplating of brazing joint possible, Narrow gap (0,03 - 0,1mm), Gap length (> 1 cm) |
HVACR, Step brazing, Heat exchangers, Copper pipes installations |
700 |
650 - 700 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
A 204 |
L-CuP8 |
- |
CP 201 |
- |
CuP 182 |
- |
- |
Excellent flow characteristics, High fluidity, Low temperature melting, Low ductility, Narrow gap (0,03 - 0,1mm), Gap length (> 1 cm) |
HVACR, Vibration free components, Especially used for wetting of large surfaces with narrow gaps |
720 |
710 - 770 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
A 407L (4) |
L-AlSi12 |
BAISi-4 |
AL 104 |
- |
Al 112 |
- |
- |
Capillary active, Color matching with aluminum |
HVAC vehicle, Heat exchangers Al/CrNi steel assemblies, For Aluminum base materials with Mg content < 3% and Solidus temperature > 630°C |
590 |
575 - 585 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
A 631 (5) |
- |
- |
- |
- |
S-Zn98Al2 |
- |
- |
Low temperature aluminum solder, brazing of aluminum since the temperature delta between base and filler metals is wider. |
HVACR, Heat exchangers, Tube connections, Al/Al, Al/Cu und Al/CrNi assemblies |
- |
430 - 440 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |